Please select and order
€171.12
excl. VAT
Add to cart
Norm

ÖNORM EN ISO 13485

Issue date: 2003 11 01

Medical devices - Quality management systems - Requirements for regulatory purposes (ISO 13485:2003)

1.1 General This International Standard specifies requirements for a quality management system where an organization needs to demonstrate its ability to provide medical...
Withdrawn: 2007 11 01
§ Legal References
1.1 General This International Standard specifies requirements for a quality management system where an organization needs to demonstrate its ability to provide medical devices and related services that consistently meet customer requirements and regulatory requirements applicable to medical devices and related services. The primary objective of this International Standard is to facilitate harmonized medical device regulatory requirements for quality management systems. As a result, it includes some particular requirements for medical devices and excludes some of the requirements of ISO 9001 that are not appropriate as regulatory requirements. Because of these exclusions, organizations whose quality management systems conform to this International Standard cannot claim conformity to ISO 9001 unless their quality management systems conform to all the requirements of ISO 9001 (see Annex B). 1.2 Application All requirements of this International Standard are specific to organizations providing medical devices, regardless of the type or size of the organization. If regulatory requirements permit exclusions of design and development controls (see 7.3), this can be used as a justification for their exclusion from the quality management system. These regulations can provide alternative arrangements that are to be addressed in the quality management system. It is the responsibility of the organization to ensure that claims of conformity with this International Standard reflect exclusion of design and development controls [see 4.2.2 a) and 7.3]. If any requirement(s) in Clause 7 of this International Standard is(are) not applicable due to the nature of the medical device(s) for which the quality management system is applied, the organization does not need to include such a requirement(s) in its quality management system [see 4.2.2 a)]. The processes required by this International Standard, which are appli (...abbreviated)
ÖVE/ÖNORM EN ISO 13485
2022 02 01
Medical devices - Quality management systems - Requirements for regulatory purposes (ISO 13485:2016)...
Norm
ÖVE/ÖNORM EN ISO 13485
2017 08 01
Medical devices - Quality management systems - Requirements for regulatory purposes (ISO 13485:2016)...
Norm
ÖVE/ÖNORM EN ISO 13485
2016 07 01
Medical devices - Quality management systems - Requirements for regulatory purposes (ISO 13485:2016)...
Norm
ÖNORM EN ISO 13485
2012 11 01
Medical devices - Quality management systems - Requirements for regulatory purposes (ISO 13485:2003 ...
Norm
ÖNORM EN ISO 13485
2010 02 15
Medical devices - Quality management systems - Requirements for regulatory purposes (ISO 13485:2003 ...
Norm
ÖNORM EN ISO 13485
2007 11 01
Medical devices - Quality management systems - Requirements for regulatory purposes (ISO 13485:2003)...
Norm
ÖNORM EN ISO 13485
2003 11 01
Medical devices - Quality management systems - Requirements for regulatory purposes (ISO 13485:2003)...
Norm
ÖVE/ÖNORM EN ISO 13488
2001 04 01
Quality systems - Medical devices - Particular requirements for the application of EN ISO 9002 (revi...
Norm
ÖVE/ÖNORM EN ISO 13485
2001 04 01
Quality systems - Medical devices - Particular requirements for the application of EN ISO 9001 (revi...
Norm
ÖNORM EN 46002
1996 12 01
Quality systems - Medical devices - Particular requirements for the application of EN ISO 9002
Norm
ÖNORM EN 46001
1996 12 01
Quality systems - Medical devices - Particular requirements for the application of EN ISO 9001
Norm
ÖNORM EN 46001
1996 12 01
Quality systems - Medical devices - Particular requirements for the application of EN ISO 9001
Norm
ÖNORM EN 46002
1996 12 01
Quality systems - Medical devices - Particular requirements for the application of EN ISO 9002
Norm
ÖNORM EN 46001
1994 02 01
Quality systems - Medical devices - Particular requirements for the application of EN 29001
Norm
ÖNORM EN 46001
1994 02 01
Quality systems - Medical devices - Particular requirements for the application of EN 29001
Norm
ÖNORM EN 46002
1994 02 01
Quality systems - Medical devices - Particular requirements for the application of EN 29002
Norm
ÖNORM EN 46002
1994 02 01
Quality systems - Medical devices - Particular requirements for the application of EN 29002
Norm
Expand
Norm
ÖNORM EN ISO 9000
Issue date : 2005 12 01
Quality management systems - Fundamentals and vocabulary (ISO 9000:2005) (multilingual version: de/en/fr)
Norm
ISO 9000:2000
Issue date : 2000 12 08
Quality management systems — Fundamentals and vocabulary
Norm
ÖNORM EN ISO 13485
Issue date : 2007 11 01
Medical devices - Quality management systems - Requirements for regulatory purposes (ISO 13485:2003) (consolidated version)
Norm
ISO 13485:2003
Issue date : 2003 07 03
Medical devices — Quality management systems — Requirements for regulatory purposes
Verordnung
Verordnung des Bundesministers für Wirtschaft und Arbeit über die Akkreditierung des TÜV Österreich zur Zertifizierung von Managementsystemen
Verordnung
Verordnung des Bundesministers für Wirtschaft und Arbeit über die Akkreditierung der Quality Austria - Trainings, Zertifizierungs und Begutachtungs GmbH (Quality Austria) zur Zertifizierung