ÖNORM EN ISO 11140-6

Issue date: 2023 04 15

Sterilization of health care products - Chemical indicators - Part 6: Type 2 indicators and process challenge devices for use in performance testing of small steam sterilizers (ISO 11140-6:2022)

This document specifies the performance requirements and test methods for hollow devices and porous devices as well as the chemical indicators and biological indicators t...
Valid
Publisher:
Austrian Standards International
Format:
Digital | 52 Pages
Language:
German | English | Download GER/ENG
This document specifies the performance requirements and test methods for hollow devices and porous devices as well as the chemical indicators and biological indicators that are utilized within these devices for testing a specific steam penetration performance of type B cycles and some type S cycles of small steam sterilizers according to EN 13060. a) Chemical indicators used with a porous device specified in this document are designed to demonstrate the adequacy of steam penetration into a porous device in small steam sterilizers (see EN 13060). This document specifies the requirements for: - a reference porous device (RPD) as a reference device by which alternative porous indicator systems (APISs) can be shown to be equivalent in performance according to this document, i.e. a textile test pack in which steam penetration is judged by thermometric means; - an alternative porous chemical indicator system equivalent in performance to the RPD, i.e. an APIS, usually commercially manufactured, of any design. b) Chemical indicators used with a hollow load device specified in this document are designed to demonstrate the adequacy of steam penetration into a narrow lumen (previously known as hollow load A) in small steam sterilizers (see EN 13060). This document specifies the requirements for: - a reference hollow device (RHD) used as a reference device in this document, i.e. a lumened device with attached capsule in which steam penetration is judged by inactivation or survival of a specified biological indicator; - an alternative hollow device: - employing the same specific test load as defined for the RHD and a chemical indicator designed specifically for use in the reference hollow test load, i.e. a lumened device with an attached capsule in which steam penetration is judged by visual examination of a chemical indicator; - equivalent in performance to the RHD, i.e. an alternative hollow device, usually commercially manufactured, of any design.
ÖNORM EN ISO 11140-6
2023 04 15
Sterilization of health care products - Chemical indicators - Part 6: Type 2 indicators and process ...
Norm
ÖNORM EN 867-5
2001 11 01
Non-biological systems for use in sterilizers - Part 5: Specification for indicator systems and proc...
Norm
Norm
ISO 10012:2003
Issue date : 2003 04 14
Measurement management systems — Requirements for measurement processes and measuring equipment
Norm
ISO 11138-3:2017
Issue date : 2017 03 03
Sterilization of health care products — Biological indicators — Part 3: Biological indicators for moist heat sterilization processes
Norm
ISO 11140-1:2014
Issue date : 2014 10 31
Sterilization of health care products — Chemical indicators — Part 1: General requirements
Norm
ISO 11140-4:2007
Issue date : 2007 03 15
Sterilization of health care products — Chemical indicators — Part 4: Class 2 indicators as an alternative to the Bowie and Dick-type test for detection of steam penetration
Norm
ISO 18472:2018
Issue date : 2018 08 16
Sterilization of health care products — Biological and chemical indicators — Test equipment