ÖNORM EN 867-5
Issue date: 2001 11 01
Non-biological systems for use in sterilizers - Part 5: Specification for indicator systems and process challenge devices for use in performance testing for small sterilizers Type B and Type S
This European Standard specifies the performance requirements and test methods for non-biological indicator
systems, including the process challenge devices within which...
Withdrawn: 2023 04 15
Publisher:
Austrian Standards International
Format:
Digital | 25 Pages
Language:
German
| English
| Download GER/ENG
Currently valid:
Optionally co-design standards:
ICS
This European Standard specifies the performance requirements and test methods for non-biological indicator
systems, including the process challenge devices within which they are intended to function, to be used for testing the
steam penetration performance of small steam sterilizers, Type B or Type S where appropriate. The test systems
specified are intended for use only in small steam sterilizers Type B conforming to prEN 13060-2 and having a usable
chamber space greater than 10 l and for small steam sterilizers Type S conforming to prEN 13060-4 also having a
usable chamber space greater than 5 l.
Non-biological indicator systems and the associate process challenge devices are specified for various types of load.
The possible loads are considered in two classes: Porous loads, which can be wrapped or unwrapped, or hollow
instrument loads, which also can be wrapped or unwrapped.
The relevant section of this European Standard on porous loads specifies the requirements for:
a standard process challenge device to be used in the small load test for porous loads in small steam sterilizers;
an indicator system for use in the porous load process challenge device. An indicator for this purpose is a Class
B indicator as described in EN 867-1.
an indicator employing an alternative process challenge device equivalent to the porous load process challenge
device.
The relevant section of this European Standard on hollow instruments specifies the requirements for:
hollow load process challenge devices to be used to simulate hollow instrument loads as defined in prEN 13060-
4;
an indicator system, for use in one of the hollow load process challenge device, for assessing steam penetration
in a wrapped load of hollow instruments. An indicator for this purpose is a Class B indicator as described in
EN 867-1.
The process challenge devices described in this standard are intended for use only in sterilizers (.. (...abbreviated)
ÖNORM EN ISO 11140-6
2023 04 15
Sterilization of health care products - Chemical indicators - Part 6: Type 2 indicators and process ...
Norm
ÖNORM EN 867-5
2001 11 01
Non-biological systems for use in sterilizers - Part 5: Specification for indicator systems and proc...
Norm
↖
Norm
Issue date :
1994 03 01
Paper, board and pulps - Standard atmosphere for conditioning and testing and procedure for monitoring the atmosphere and conditioning of samples (ISO 187:1990)
Norm
Issue date :
2006 11 01
Sterilization of health care products - Biological indicators - Part 3: Biological indicators for moist heat sterilization processes (ISO 11138-3:2006)
Norm
Issue date :
2007 06 01
Sterilization of health care products - Chemical indicators - Part 4: Class 2 indicators as an alternative to the Bowie and Dick-type test for detection of steam penetration (ISO 11140-4:2007)
Norm
Issue date :
1995 08 01
Water for analytical laboratory use - Specifications and test methods (ISO 3696:1987)
Norm
Issue date :
2005 05 01
Paper and board - Determination of thickness, density and specific volume (ISO 534:2005)
Norm
Issue date :
1999 11 01
Technical product documentation - Sizes and layout of drawing sheets (ISO 5457:1999)
Norm
Issue date :
2023 04 15
Sterilization of health care products - Chemical indicators - Part 6: Type 2 indicators and process challenge devices for use in performance testing of small steam sterilizers (ISO 11140-6:2022)