Please select and order
€232.70
excl. VAT
Add to cart
Norm

ÖVE/ÖNORM EN 62423

Issue date: 2013 09 01

Type F and type B residual current operated circuit-breakers with and without integral overcurrent protection for household and similar uses (IEC 62423:2009, mod. + corrigendum Dec. 2011) (english version)

The scope of IEC 61008-1 and IEC 61009-1 applies with the following additions. This standard specifies requirements and tests for Type F and Type B RCDs (Residual Curre...
Withdrawn: 2024 03 01
The scope of IEC 61008-1 and IEC 61009-1 applies with the following additions. This standard specifies requirements and tests for Type F and Type B RCDs (Residual Current Devices). Requirements and tests given in this standard are in addition to the requirements of Type A residual current devices. This standard can only be used together with IEC 61008-1 and IEC 61009-1. Type F RCCBs (Residual Current Circuit Breaker) and Type F RCBOs (Residual current Circuit Breaker with Overcurrent protection) with rated frequency 50 Hz or 60 Hz are intended for installations when frequency inverters are supplied between phase and neutral or phase and earthed middle conductor and are able to provide protection in case of alternating residual sinusoidal at the rated frequency, pulsating direct residual currents and composite residual currents that may occur. Type B RCCBs and Type B RCBOs are able to provide protection in case of alternating residual sinusoidal currents up to 1 000 Hz, pulsating direct residual currents and smooth direct residual currents. RCDs according to this standard are not intended to be used in d.c. supply systems. Further requirements and tests for products to be used in situations where the residual current was not intended to be covered in IEC 61008-1 or IEC 61009-1 are under consideration. For the purpose of manufacturer’s declaration or verification of conformity, type tests should be carried out in test sequences in compliance with Annex A, Annex B, Annex C or Annex D of this standard. The complete test sequence for type test of Type F RCCBs and Type F RCBOs is given in Tables A.1 and B.1 respectively. The complete test sequence for type test of Type B RCCBs and Type B RCBOs is given in Tables C.1 or D.1 respectively.
OVE EN 62423
2024 01 01
Type F and type B residual current operated circuit-breakers with and without integral overcurrent p...
Norm
OVE EN 62423
2024 01 01
Type F and type B residual current operated circuit-breakers with and without integral overcurrent p...
Norm
OVE EN 62423
2022 04 01
Type F and type B residual current operated circuit-breakers with and without integral overcurrent p...
Norm
OVE EN 62423
2022 04 01
Type F and type B residual current operated circuit-breakers with and without integral overcurrent p...
Norm
ÖVE/ÖNORM EN 62423
2013 09 01
Type F and type B residual current operated circuit-breakers with and without integral overcurrent p...
Norm
ÖVE/ÖNORM EN 62423
2010 09 01
Type B residual current operated circuit-breakers with and without integral overcurrent protection f...
Norm
ÖVE/ÖNORM EN 62423
2010 09 01
Type B residual current operated circuit-breakers with and without integral overcurrent protection f...
Norm
Expand
Norm
OVE EN 62423
Issue date : 2022 04 01
Type F and type B residual current operated circuit-breakers with and without integral overcurrent protection for household and similar uses (german version)
Norm
OVE EN 62423
Issue date : 2022 04 01
Type F and type B residual current operated circuit-breakers with and without integral overcurrent protection for household and similar uses (english version)