Please select and order
€120.67
excl. VAT
Add to cart
Norm
ÖVE/ÖNORM EN 61526
Issue date: 2007 10 01
Radiation protection instrumentation - Measurement of personal dose equivalents Hp(10) and Hp(0,07) for X, gamma, neutron and beta radiations - Direct reading personal dose equivalent meters and monitors (IEC 61526:2005, modified)
Diese ÖVE/ÖNORM gilt für Personendosimeter mit den folgenden Eigenschaften: a) Sie werden am Rumpf oder an den Gliedmaßen des Körpers getragen. b) Sie messen die Tiefen- ...
Withdrawn: 2015 12 01
Publisher:
Austrian Standards International
Format:
Digital | 70 Pages
Language:
German
Currently valid:
Optionally co-design standards:
Diese ÖVE/ÖNORM gilt für Personendosimeter mit den folgenden Eigenschaften: a) Sie werden am Rumpf oder an den Gliedmaßen des Körpers getragen. b) Sie messen die Tiefen- und Oberflächen-Personendosis Hp(10) und Hp(0,07) durch externe Röntgen-, Gamma-, Neutronen- und Betastrahlung und können die Tiefen- und Oberflächen-Personendosisleistungen Hp(10) und Hp(0,07) messen. c) Sie haben eine digitale Anzeige. d) Sie können Warnschwellen für die Personendosis oder die Personendosisleistung haben. Diese Norm ist daher für die Messung der folgenden Kombinationen von Dosismessgrößen (einschließlich der zugehörigen Dosisleistungen) und Strahlungsarten anwendbar. 1) Hp(10) und Hp(0,07) durch Röntgen- und Gammastrahlung, 2) Hp(10) und Hp(0,07) durch Röntgen-, Gamma- und Betastrahlung, 3) Hp(10) durch Röntgen- und Gammastrahlung, 4) Hp(10) durch Neutronenstrahlung, 5) Hp(10) durch Röntgen-, Gamma- und Neutronenstrahlung, 6) Hp(10) durch Röntgen-, Gamma- und Betastrahlung. Diese Norm legt Anforderungen für Dosimeter und, sofern mitgeliefert, für dazugehörige Auswertegeräte fest. Diese Norm enthält für die oben beschriebenen Dosimeter allgemeine Leistungsmerkmale, allgemeine Prüfverfahren, Merkmale für Eigenschaften bezüglich Strahlung sowie bezüglich elektrischer, mechanischer, sicherheitstechnischer und umgebungsspezifischer Parameter.
ÖVE/ÖNORM EN 61526
2013 11 01
Radiation protection instrumentation - Measurement of personal dose equivalents Hp(10) and Hp(0,07) ...
Norm
ÖVE/ÖNORM EN 61526
2013 11 01
Radiation protection instrumentation - Measurement of personal dose equivalents Hp(10) and Hp(0,07) ...
Norm
ÖVE/ÖNORM EN 61526
2007 10 01
Radiation protection instrumentation - Measurement of personal dose equivalents Hp(10) and Hp(0,07) ...
Norm
↖
ÖNORM S 5237-1
1998 11 01
Radiation protection dosimeters - Personal dosimeters for the measurement of the personal dose equiv...
Norm
Norm
Issue date :
2008 03 04
Reference radiation fields — Simulated workplace neutron fields — Part 2: Calibration fundamentals related to the basic quantities
Norm
Issue date :
1996 12 12
X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy — Part 1: Radiation characteristics and production methods
Norm
Issue date :
1997 12 18
X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy — Part 2: Dosimetry for radiation protection over the energy ranges from 8 keV to 1,3 MeV and 4 MeV to 9 MeV
Norm
Issue date :
1999 07 01
X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy — Part 3: Calibration of area and personal dosemeters and the measurement of their response as a function of energy and angle of incidence
Norm
Issue date :
1996 10 10
Reference beta radiations for calibrating dosemeters and dose-rate meters and for determining their response as a function of beta-radiation energy
Norm
Issue date :
2001 02 01
Reference neutron radiations — Part 1: Characteristics and methods of production
Norm
Issue date :
2000 08 24
Reference neutron radiations — Part 2: Calibration fundamentals of radiation protection devices related to the basic quantities characterizing the radiation field
Norm
Issue date :
1998 12 03
Reference neutron radiations — Part 3: Calibration of area and personal dosimeters and determination of response as a function of energy and angle of incidence
Norm
Issue date :
2000 11 30
Reference neutron radiations — Characteristics and methods of production of simulated workplace neutron fields
Norm
Issue date :
2008 03 04
Reference radiation fields — Simulated workplace neutron fields — Part 2: Calibration fundamentals related to the basic quantities
Norm
Issue date :
2013 11 01
Radiation protection instrumentation - Measurement of personal dose equivalents Hp(10) and Hp(0,07) for X, gamma, neutron and beta radiations - Direct reading personal dose equivalent meters (IEC 61526:2010, modified) (german version)
Norm
Issue date :
2013 11 01
Radiation protection instrumentation - Measurement of personal dose equivalents Hp(10) and Hp(0,07) for X, gamma, neutron and beta radiations - Direct reading personal dose equivalent meters (IEC 61526:2010, modified) (english version)