ÖVE/ÖNORM EN 50396

Issue date: 2012 04 01

Non electrical test methods for low voltage energy cables (english version)

EN 50396 contains non-electrical test methods required for the testing of harmonized low voltage energy cables, especially those rated at up to and including 450/750 V. ...
Valid
Publisher:
Austrian Standards International
Format:
Digital | 52 Pages
Language:
English
EN 50396 contains non-electrical test methods required for the testing of harmonized low voltage energy cables, especially those rated at up to and including 450/750 V. The particular cable standard dictates the tests which need to be performed on the relevant cable type. It also specifies whether the specific test is a type test (T), a sample test (S) or a routine test (R) for the particular cable type. The requirements to be met during or after the test are specified for the particular cable type in the relevant cable standard. However, some test requirements are obvious and universal, such as the fact that no cracks shall occur during ozone test, and these are stated in the particular test method. Test methods for use specifically in utility power cables are not covered by this EN. They can be found in HD 605. Test methods for use specifically in communications cables are the responsibility of CENELEC TC 46X. At present such test methods are given in EN 50289 (series).
ÖVE/ÖNORM EN 50396
2012 04 01
Non electrical test methods for low voltage energy cables (english version)
Norm
ÖVE/ÖNORM EN 50396
2006 09 01
Non electrical test methods for low voltage energy cables
Norm
ÖVE/ÖNORM E 8240-2/A1
2003 11 01
Cables of rated voltages up to and including 450/750 V and having cross-linked insulation - Part 2: ...
Norm
ÖVE/ÖNORM E 8241-2+A1
2003 11 01
Cables of rated voltages up to and including 450/750 V and having thermoplastic insulation - Part 2:...
Norm
ÖVE K 40-2
1998 06
Rubber insulated cables of rated voltages up to and including 450/750 V - Part 2: Test methods
Technische Regel
ÖVE K 41-2
1998 06
Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 2: Test m...
Technische Regel
ÖVE K 40-2
1994 11
Energieleitungen mit einer Isolierung aus Gummi - Prüfverfahren
Technische Regel
ÖVE K 41-2
1994 11
Energieleitungen mit einer Isolierung aus PVC - Prüfverfahren
Technische Regel
ÖVE K 70-5a
1993 05
Prüfverfahren für Kabel, isolierte Leitungen und isolierte Drähte - Prüfung des Verhaltens gegenüber...
Technische Regel
ÖVE K 70-6
1993 05
Prüfverfahren für Kabel, isolierte Leitungen und isolierte Drähte - Sonstige Prüfungen
Technische Regel
ÖVE K 40a/1982
1982 10 01
Nachtrag a zu den Bestimmungen über Energieleitungen mit einer Isolierung aus Gummi, ÖVE-K 40/1978
Technische Regel
ÖVE K 40/1978
1978 01 01
Energieleitungen mit einer Isolierung aus Gummi - einschließlich des Nachtrages ÖVE-K 40a/1982
Technische Regel
Expand