Cryogenic vessels - Pressure-relief accessories for cryogenic service - Part 3: Sizing and capacity determination (ISO 21013-3:2016)

This part of ISO 21013 provides separate calculation methods for determining the required mass flow to be relieved for each of the following specified conditions. - Vacu...
Valid
Publisher:
Austrian Standards International
Format:
Digital | 49 Pages
Language:
German | English | Download GER/ENG
This part of ISO 21013 provides separate calculation methods for determining the required mass flow to be relieved for each of the following specified conditions. - Vacuum-insulated vessels with insulation system (outer jacket + insulating material) intact under normal vacuum; outer jacket at ambient temperature; inner vessel at temperature of the contents at the relieving pressure. - Vacuum-insulated vessels with insulation system (outer jacket + insulating material) intact under normal vacuum; outer jacket at ambient temperature; inner vessel at temperature of the contents at the relieving pressure; pressure regulator of the pressure build-up system functioning at full potential. - Vacuum or non-vacuum-insulated vessels with insulation system remaining in place, but with loss of vacuum in the case of vacuum-insulated vessels, outer jacket at ambient temperature, inner vessel at temperature of the contents at the relieving pressure. OR: Vacuum or non-vacuum-insulated vessels with insulation system remaining fully or partially in place, but with loss of vacuum in the case of vacuum-insulated vessels, fire engulfment; inner vessel at temperature of the contents at the relieving pressure. - Vacuum-insulated vessels containing fluids with saturation temperature below 75 K at 1 bar with insulation system remaining in place, but with loss of vacuum with air in the vacuum space. - Vacuum insulated vessels containing fluids with saturation temperature below 75 K at 1 bar with insulation system remaining in place, but with loss of vacuum with air in the vacuum space with fire engulfment. - Vessels with insulation system totally lost and fire engulfment. Good engineering practice based on well-established theoretical physical science shall be adopted to determine the required mass flow where an appropriate calculation method is not provided for an applicable condition. Cryostats can be considered pressure vessels for application of this standard. Additional upset conditions (quenching, etc.) and resulting heat transfer shall be considered in the calculations.
ÖNORM EN ISO 21013-3
2016 11 01
Cryogenic vessels - Pressure-relief accessories for cryogenic service - Part 3: Sizing and capacity ...
Norm
ÖNORM EN 13648-3
2003 02 01
Cryogenic vessels - Safety devices for protection against excessive pressure - Part 3: Determination...
Norm
Norm
ISO 21013-3:2016
Issue date : 2016 05 12
Cryogenic vessels — Pressure-relief accessories for cryogenic service — Part 3: Sizing and capacity determination