Please select and order
€185.23
excl. VAT
Add to cart
Norm
ÖNORM EN 1993-5
Issue date: 2012 03 01
Eurocode 3 - Design of steel structures - Part 5: Piling (consolidated version)
(1) Part 5 of EN 1993 provides principles and application rules for the structural design of bearing piles
and sheet piles made of steel.
(2) It also provides examples ...
Valid
Publisher:
Austrian Standards International
Format:
Digital | 96 Pages
Language:
German
| English
| Download GER/ENG
Optionally co-design standards:
(1) Part 5 of EN 1993 provides principles and application rules for the structural design of bearing piles
and sheet piles made of steel.
(2) It also provides examples of detailing for foundation and retaining wall structures.
(3) The field of application includes:
- steel piled foundations for civil engineering works on land and over water;
- temporary or permanent structures needed to carry out steel piling work;
- temporary or permanent retaining structures composed of steel sheet piles, including all kinds of
combined walls.
(4) The field of application excludes:
- offshore platforms;
- dolphins.
(5) Part 5 of EN 1993 also includes application rules for steel piles filled with concrete.
(6) Special requirements for seismic design are not covered. Where the effects of ground movements
caused by earthquakes are relevant see EN 1998.
(7) Design provisions are also given for walings, bracing and anchorages, see section 7.
(8) The design of steel sheet piling using class 1, 2 and 3 cross-sections is covered in sections 5 and 6,
whereas the design of class 4 cross-sections is covered in annex A.
NOTE: The testing of class 4 sheet piles is covered in annex B.
(9) The design procedures for crimped U-piles and straight web steel sheet piles utilise design resistances
obtained by testing. Reference should be made to EN 10248 for testing procedures.
(10) Geotechnical aspects are not covered in this document. Reference is made to EN 1997.
(11) Provisions for taking into account the effects of corrosion in the design of piling are given in section 4.
(12) Allowance for plastic global analysis in accordance with 5.4.3 of EN 1993-1-1 is given in 5.2.
NOTE: Guidance for the design of steel sheet pile walls allowing for plastic global analysis is given in
Annex C.
(13) The design of combined walls at ultimate limit states is covered in section 5 including general
provisions for the design of primary elements.
NOTE: Guidance for the design of both tubular piles and I-sections used as primary elements is given in
Annex D.
ÖNORM EN 1993-5
2012 03 01
Eurocode 3 - Design of steel structures - Part 5: Piling (consolidated version)
Norm
↖
Norm
Issue date :
1999 08 01
Execution of special geotechnical work - Sheet-pile walls
Norm
Issue date :
2001 07 01
Execution of special geotechnical work - Displacement piles
Norm
Issue date :
2012 03 01
Eurocode 3: Design of steel structures - Part 1-2: General rules - Structural fire design (consolidated version)
Norm
Issue date :
2012 03 01
Eurocode 3: Design of steel structures - Part 1-8: Design of joints (consolidated version)
Norm
Issue date :
2005 11 01
Eurocode 3: Design of steel structures - Part 1-9: Fatigue
Norm
Issue date :
2010 08 15
Eurocode 3 - Design of steel structures - Part 1-10: Material toughness and through-thickness properties (consolidated version)
Norm
Issue date :
2010 09 01
Eurocode 3 - Design of steel structures - Part 1-3: General rules - Supplementary rules for cold-formed members and sheeting (consolidated version)
Norm
Issue date :
2007 04 01
Eurocode 3: Design of steel structures - Part 1-5: Plated structural elements
Norm
Issue date :
2010 06 01
Eurocode 3 - Design of steel structures - Part 1-11: Design of structures with tension components (consolidated version)
Norm
Issue date :
2007 10 01
Eurocode 3: Design of steel structures - Part 1-6: Strength and Stability of Shell Structures
Norm
Issue date :
2012 01 01
Execution of steel structures and aluminium structures - Part 2: Technical requirements for steel structures