Please select and order
€372.30
excl. VAT
Add to cart
Norm
ÖNORM EN 17082
Issue date: 2020 03 15
Domestic and non-domestic gas-fired forced convection air heaters for space heating not exceeding a net heat input of 300 kW
This document specifies the requirements and test methods for the safety and efficiency of gas fired air heaters with or without a fan to assist the transportation of com...
Withdrawn: 2020 04 15
Publisher:
Austrian Standards International
Format:
Digital | 207 Pages
Language:
German
| English
| Download GER/ENG
Currently valid:
Optionally co-design standards:
ICS
This document specifies the requirements and test methods for the safety and efficiency of gas fired air heaters with or without a fan to assist the transportation of combustion air and/or flue gases, hereafter referred to as "appliances".
This document also applies to warm air heaters having forced draught burners.
This document applies to Type A2, A3 appliances, with an input not exceeding 300 kW (net CV basis), intended for non-domestic use.
This document also applies to Type B11, B11AS, B11BS, B12, B12AS, B12BS, B13, B13AS, B13BS, B14, B14AS, B14BS, B22, B23, B41, B41AS, B41BS, B42, B42AS, B42BS, B43, B43AS, B43BS, B44, B44AS, B44BS, B52, B53, C11, C12, C13, C21, C31, C32, C33, C41, C62 and C63 appliances with an input not exceeding 300 kW (net CV basis), intended for domestic and non-domestic use.
Provision of the heated air may be by means of ducting.
This document does not apply to:
a) dual purpose air conditioning appliances (heating and cooling);
b) appliances where the air is heated by an intermediate fluid;
c) portable or transportable forced convection appliances;
d) appliances fitted with manual or automatic means of adjusting the combustion productsevacuation by means of flue dampers;
e) appliances having multiple heating units with a single draught diverter;
f) appliances fitted with more than one flue outlet;
g) appliances fitted with gas boosters;
h) C21 and C41 appliances for 3rd family gases.
ÖNORM EN 17082
2020 04 15
Domestic and non-domestic gas-fired forced convection air heaters for space heating not exceeding a ...
Norm
ÖNORM EN 17082
2020 03 15
Domestic and non-domestic gas-fired forced convection air heaters for space heating not exceeding a ...
Norm
↖
ÖNORM EN 1196
2011 11 01
Domestic and non-domestic gas-fired air heaters - Supplementary requirements for condensing air heat...
Norm
ÖNORM EN 778
2011 04 01
Domestic gas-fired forced convection air heaters for space heating not exceeding a net heat input of...
Norm
ÖNORM EN 621
2011 03 15
Non-domestic gas-fired forced convection air heaters for space heating not exceeding a net heat inpu...
Norm
ÖNORM EN 1020
2010 12 01
Non-domestic forced convection gas-fired air heaters for space heating not exceeding a net heat inpu...
Norm
ÖNORM EN 1319
2010 10 15
Domestic gas-fired forced convection air heaters for space heating, with fan-assisted burners not ex...
Norm
ÖNORM EN 525
2010 05 15
Non-domestic direct gas-fired forced convection air heaters for space heating not exceeding a net he...
Norm
ÖNORM EN 1020
2010 03 01
Non-domestic forced convection gas-fired air heaters for space heating not exceeding a net heat inpu...
Norm
ÖNORM EN 621/A1
2001 12 01
Non-domestic gas-fired forced convection air heaters for space heating not exceeding a net heat inpu...
Norm
ÖNORM EN 1020/A1
2001 12 01
Non-domestic gas-fired forced convection air heaters for space heating not exceeding a net heat inpu...
Norm
ÖNORM EN 1319/A1
2001 12 01
Domestic gas-fired forced convection air heaters for space heating, with fan-assisted burners not ex...
Norm
ÖNORM EN 778/A1
2001 12 01
Domestic gas-fired forced convection air heaters for space heating not exceeding a net heat input of...
Norm
ÖNORM EN 1319/A2
1999 12 01
Domestic gas-fired forced convection air heaters for space heating, with fan-assisted burners not ex...
Norm
ÖNORM EN 1319
1998 10 01
Domestic gas-fired forced convection air heaters for space heating, with fan-assisted burners not ex...
Norm
ÖNORM EN 1196
1998 08 01
Domestic and non-domestic gas-fired air heaters - Supplementary requirements for condensing air heat...
Norm
ÖNORM EN 778
1998 03 01
Domestic gas-fired forced convection air heaters for space heating not exceeding a net heat input of...
Norm
ÖNORM EN 1020
1998 03 01
Non-domestic gas-fired convection air heaters for space heating not exceeding a net heat input of 30...
Norm
ÖNORM EN 621
1998 03 01
Non-domestic gas-fired convection air heaters for space heating not exceeding a net heat input of 30...
Norm
ÖNORM EN 525
1997 12 01
Non-domestic direct gas-fired forced convection air heaters for space heating not exceeding a net he...
Norm
ÖNORM M 7446
1992 05 01
Condensing appliances for gaseous fuels - Requirements, disposal of condensate, flue ducting, testin...
Norm
ÖNORM M 7451-1
1985 09 01
Stationary gas-fired fan-assisted air heaters with atmospheric burners
Norm
ÖNORM M 7451-1
1985 09 01
Stationary gas-fired fan-assisted air heaters with atmospheric burners
Norm
ÖNORM M 7446
1985 04 01
Condensing appliances for gaseous fuels; requirements, disposal of condensate and flue ducting, test...
Vornorm
Norm
Issue date :
2008 07 10
Measurement of fluid flow in closed conduits — Velocity area method using Pitot static tubes
Norm
Issue date :
2011 07 15
Pipe flanges — Part 1: Steel flanges for industrial and general service piping systems
Norm
Issue date :
1988 02 18
Metallic flanges — Part 3: Copper alloy and composite flanges
Norm
Issue date :
2020 04 15
Domestic and non-domestic gas-fired forced convection air heaters for space heating not exceeding a net heat input of 300 kW