Please select and order
€229.44
excl. VAT
Add to cart
Norm
ÖNORM EN 16351
Issue date: 2015 11 15
Timber structures - Cross laminated timber - Requirements
This European Standard sets out provisions regarding the performance characteristics for straight and curved structural cross laminated timber (X-Lam) both without and wi...
Withdrawn: 2021 07 01
Publisher:
Austrian Standards International
Format:
Digital | 107 Pages
Language:
German
| English
Currently valid:
Optionally co-design standards:
ICS
This European Standard sets out provisions regarding the performance characteristics for straight and curved structural cross laminated timber (X-Lam) both without and with large finger joints as a material for the manufacture of structural elements to be used in buildings and bridges.
This European Standard applies to cross laminated timber:
- to be used in service class 1 or 2 according to EN 1995-1-1;
- made of coniferous species and poplar listed in 5.1.5 of this standard;
- built up of at least three orthogonally bonded layers (at least two of them timber layers);
- having, depending on the number of layers, adjacent layers which may be bonded parallel to the grain;
- made of timber layers which are made of strength graded timber according to EN 14081-1;
- made of timber layers having thicknesses between 6 mm and 60 mm (including) taking into account the layup requirements given in this European standard;
- made of timber layers which may be edge bonded or which are not bonded and have spacing less than 6 mm between adjacent laminations;
- which may comprise wood based panel layers made of structural wood based panels specified in this European standard, fulfilling the requirements for use in service class 2 or 3 according to EN 1995-1-1, having no structural joints between the single panels and having thicknesses between 6 mm and 45 mm (including);
- bonded with adhesives, fulfilling the requirements given in this European standard;
- having overall thicknesses up to 500 mm;
- which is not made from reused timber or wood based panels comprising reused timber.
This European Standard also applies to cross laminated timber with large finger joints:
- made from cross laminated timber pieces having the same cross section and layup;
- made from cross laminated timber pieces having cross sectional thicknesses from 51 mm up to 345 mm (inclusive) and minimum thicknesses of the outermost layers not less than 17 mm.
- made from cross laminated timber pieces solely comprising timber layers;
- made from plane cross laminated timber pieces jointed so that no regular change between the grain directions of the layers occurs;
- with finger joints having a finger length of at least 45 mm and fingers which are visible at the two narrow sides of the components.
This European Standard applies to cross laminated timber treated against biological attack. Cross laminated timber treated with fire retardants is not covered.
It also sets out minimum production requirements and procedures for Assessment and Verification of Constancy of Performance.
Norm
Issue date :
1994 12 01
Durability of wood and wood-based products - Natural durability of solid wood - Part 1: Guide to the principles of testing and classification of the natural durability of wood
Norm
Issue date :
1994 12 01
Durability of wood and wood-based products - Natural durability of solid wood - Part 2: Guide to natural durability and treatability of selected wood species of ......(abbreviated)
Norm
Issue date :
2005 04 01
Timber structures - Test methods - Determination of mechanical properties of wood based panels
Norm
Issue date :
2002 07 01
Moisture content of a piece of sawn timber - Part 2: Estimation by electrical resistance method
Norm
Issue date :
2004 02 01
Moisture content of a piece of sawn timber - Part 1: Determination by oven dry method (EN 13183-1:2002 + AC:2003)
Norm
Issue date :
2013 05 01
Adhesives for load-bearing timber structures - Test methods - Part 6: Determination of the minimum pressing time under referenced conditions
Norm
Issue date :
2013 05 01
Adhesives for load-bearing timber structures - Test methods - Part 4: Determination of the effects of wood shrinkage on the shear strength
Norm
Issue date :
2013 05 01
Adhesives for load-bearing timber structures - Test methods - Part 1: Determination of longitudinal tensile shear strength
Norm
Issue date :
2013 05 01
Adhesives for load-bearing timber structures - Test methods - Part 2: Determination of resistance to delamination
Norm
Issue date :
2015 06 01
Wood-based panels for use in construction - Characteristics, evaluation of conformity and marking
Norm
Issue date :
2005 02 01
Wood-based panels - Determination of formaldehyde release - Part 1: Formaldehyde emission by the chamber method
Norm
Issue date :
2005 02 01
Timber structures - Structural laminated veneer lumber - Requirements
Norm
Issue date :
2005 05 01
Moisture content of a piece of sawn timber - Part 3: Estimation by capacitance method
Norm
Issue date :
2011 03 01
Timber structures - Strength graded structural timber with rectangular cross section - Part 1: General requirements
Norm
Issue date :
2013 12 01
Adhesives, phenolic and aminoplastic, for load-bearing timber structures - Classification and performance requirements
Norm
Issue date :
2009 12 01
Fire classification of construction products and building elements - Part 1: Classification using data from reaction to fire tests
Norm
Issue date :
2009 05 15
Structural timber - Structural timber preservative treated against biological attack
Norm
Issue date :
2015 01 15
Reaction to fire tests for building products - Building products excluding floorings exposed to the thermal attack by a single burning item
Norm
Issue date :
2012 09 01
Timber structures - Structural timber and glued laminated timber - Determination of some physical and mechanical properties
Norm
Issue date :
2013 05 01
Adhesives for load-bearing timber structures - Test methods - Part 3: Determination of the effect of acid damage to wood fibres by temperature and humidity cycling on the transverse tensile strength
Norm
Issue date :
2021 07 01
Timber structures - Cross laminated timber - Requirements