Please select and order
€160.20
excl. VAT
Add to cart
Norm

ÖNORM EN 13284-1

Issue date: 2017 12 15

Stationary source emissions - Determination of low range mass concentration of dust - Part 1: Manual gravimetric method

This European Standard specifies the standard reference method (SRM) for the measurement of low dust concentration in ducted gaseous streams in the concentrations below 5...
Valid
§ Legal References
Publisher:
Austrian Standards International
Format:
Digital | 67 Pages
Language:
German | English | Download GER/ENG
Optionally co-design standards:
This European Standard specifies the standard reference method (SRM) for the measurement of low dust concentration in ducted gaseous streams in the concentrations below 50 mg/m³ at standard conditions. This European Standard is primarily developed and validated for gaseous streams emitted by waste incinerators. More generally, it can be applied to gases emitted from other stationary sources, and to higher concentrations. If the gases contain unstable, reactive or semi-volatile substances, the measurement depends on the sampling and filter treatment conditions. This method has been validated in field tests with special emphasis to dust concentrations around 5 mg/m³. The results of the field tests are presented in Annex A.
ÖNORM EN 13284-1
2017 12 15
Stationary source emissions - Determination of low range mass concentration of dust - Part 1: Manual...
Norm
ÖNORM EN 13284-1
2002 03 01
Stationary source emissions - Determination of low range mass concentration of dust - Part 1: Manual...
Norm
Verordnung
Verordnung der Bundesministerin für Klimaschutz, Umwelt, Energie, Mobilität, Innovation und Technologie, des Bundesministers für Arbeit und Wirtschaft und des Bundesministers für Land- und F