Please select and order
€268.58
excl. VAT
Add to cart
Norm
ÖNORM EN 1020
Issue date: 1998 03 01
Non-domestic gas-fired convection air heaters for space heating not exceeding a net heat input of 300 kW, incorporating a fan to assist transportation of .............(abbreviated)
This European Standard specifies the requirements and test methods for the safety and efficiency of non-domestic gas-fired air heaters having a fan to assist the transpor...
Withdrawn: 2010 03 01
Publisher:
Austrian Standards International
Format:
Digital | 142 Pages
Language:
German
| English
Currently valid:
Optionally co-design standards:
ICS
This European Standard specifies the requirements and test methods for the safety and efficiency of non-domestic gas-fired air heaters having a fan to assist the transportation of combustion air andlor flue gases, hereafter referred to as "appliances". This includes
appliances having forced draught burners. This European Standard applies to Type B12, Bl3, B14, B22, B23, C12, C13, C32, C33, C62 and C63 appliances with a heat input not exceeding 300 kW (based on net calorific value) intended for use in other than single unit residential dwellings. It also applies to appliances intended for
outdoor installation. Provision of the heated air may be by means of ducting or may be directly into the heated space.
For Type B22 appliances, this European Standard only applies to appliances having automatic ignition. For Type C62 and and C63 appliances, this European Standard only applies when such appliances are intended for final installation in a similar manner to Type C, appliances. This standard does not apply to: appliances intended for use in a single unit residential dwelling; appliances of the condensing type; appliances with atmospheric burners without a fan to assist the transportation of combustion air andlor flue gases; dual purpose air conditioning appliances (heating and cooling); appliances where the air is heated by an intermediate fluid; appliances fitted with manual or automatic flue dampers; portable or transportable forced convection appliances; appliances having multiple heating units with a single draught diverter; appliances fitted with more than one flue outlet. This European Standard is applicable to appliances which are intended to be type tested.
NOTE: Requirements for appliances which are not type tested would need to be subject to further consideration.
ÖNORM EN 17082
2020 04 15
Domestic and non-domestic gas-fired forced convection air heaters for space heating not exceeding a ...
Norm
ÖNORM EN 17082
2020 03 15
Domestic and non-domestic gas-fired forced convection air heaters for space heating not exceeding a ...
Norm
ÖNORM EN 1020
2010 12 01
Non-domestic forced convection gas-fired air heaters for space heating not exceeding a net heat inpu...
Norm
ÖNORM EN 1020
2010 03 01
Non-domestic forced convection gas-fired air heaters for space heating not exceeding a net heat inpu...
Norm
ÖNORM EN 1020
1998 03 01
Non-domestic gas-fired convection air heaters for space heating not exceeding a net heat input of 30...
Norm
↖
ÖNORM M 7451-1
1985 09 01
Stationary gas-fired fan-assisted air heaters with atmospheric burners
Norm
Norm
Issue date :
2007 04 01
Automatic shut-off valves for gas burners and gas appliances
Norm
Issue date :
2006 07 01
Automatic gas burner control systems for gas burners and gas burning appliances with or without fans
Norm
Issue date :
1994 05 12
Pipe threads where pressure-tight joints are made on the threads — Part 1: Dimensions, tolerances and designation
Norm
Issue date :
1994 05 12
Pipe threads where pressure-tight joints are not made on the threads — Part 1: Dimensions, tolerances and designation
Norm
Issue date :
1990 12 06
Fire tests — Building materials — Non-combustibility test
Norm
Issue date :
2016 08 04
Natural gas — Calculation of calorific values, density, relative density and Wobbe indices from composition
Norm
Issue date :
1988 02 18
Metallic flanges — Part 3: Copper alloy and composite flanges
Norm
Issue date :
2010 03 01
Non-domestic forced convection gas-fired air heaters for space heating not exceeding a net heat input of 300 kW incorporating a fan to assist transportation of combustion air or combustion products