ÖVE/ÖNORM EN ISO 80601-2-61

Issue date: 2012 03 01

Medical electrical equipment - Part 2-61: Particular requirements for basic safety and essential performance of pulse oximeter equipment (ISO 80601-2-61:2011) (english version)

This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of PULSE OXIMETER EQUIPMENT intended for use on humans, hereafter referred to as ME EQU...
Withdrawn: 2019 07 15
Publisher:
Austrian Standards International
Format:
Digital | 100 Pages
Language:
English
This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of PULSE OXIMETER EQUIPMENT intended for use on humans, hereafter referred to as ME EQUIPMENT. This includes any part necessary for NORMAL USE, including the PULSE OXIMETER MONITOR, PULSE OXIMETER PROBE, and PROBE CABLE EXTENDER. These requirements also apply to PULSE OXIMETER EQUIPMENT, including PULSE OXIMETER MONITORS, PULSE OXIMETER PROBES and PROBE CABLE EXTENDERS, which have been REPROCESSED. The intended use of PULSE OXIMETER EQUIPMENT includes, but is not limited to, the estimation of arterial oxygen haemoglobin saturation and pulse rate of PATIENTS in professional healthcare institutions as well as PATIENTS in the HOME HEALTHCARE ENVIRONMENT. This International Standard is not applicable to PULSE OXIMETER EQUIPMENT intended for use in laboratory research applications nor to oximeters that require a blood sample from the PATIENT. If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or to ME SYSTEMS only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME EQUIPMENT and to ME SYSTEMS, as relevant. HAZARDS inherent in the intended physiological function of ME EQUIPMENT or ME SYSTEMS within the scope of this standard are not covered by specific requirements in this standard except in 201.11 and in 7.2.13 and 8.4.1 of the general standard. This standard can also be applied to PULSE OXIMETER EQUIPMENT and their ACCESSORIES used for compensation or alleviation of disease, injury or disability. This International Standard is not applicable to PULSE OXIMETER EQUIPMENT intended solely for foetal use. This International Standard is not applicable to remote or slave (secondary) devices that display SpO2 values that are located outside of the PATIENT ENVIRONMENT. The object of this particular standard is to establish particular BASIC SAFETY and ESSENTIAL PERFORMANCE requirements for PULSE OXIMETER EQUIPMENT [as defined in 201.3.216] and its ACCESSORIES.
ÖNORM EN ISO 80601-2-61
2019 07 15
Medical electrical equipment - Part 2-61: Particular requirements for basic safety and essential per...
Norm
ÖVE/ÖNORM EN ISO 80601-2-61
2012 03 01
Medical electrical equipment - Part 2-61: Particular requirements for basic safety and essential per...
Norm
ÖNORM EN ISO 9919
2009 09 01
Medical electrical equipment - Particular requirements for the basic safety and essential performanc...
Norm
ÖNORM EN ISO 9919
2005 10 01
Medical electrical equipment - Particular requirements for the basic safety and essential performanc...
Norm
Expand
Norm
ISO 14155:2011
Issue date : 2011 01 21
Clinical investigation of medical devices for human subjects — Good clinical practice
Norm
ISO 14937:2000
Issue date : 2000 12 21
Sterilization of health care products — General requirements for characterization of a sterilizing agent and the development, validation and routine control of a sterilization process for medical devices
Norm
ISO 15223-1:2007
Issue date : 2007 04 04
Medical devices — Symbols to be used with medical device labels, labelling and information to be supplied — Part 1: General requirements
Norm
ÖNORM EN ISO 80601-2-61
Issue date : 2019 07 15
Medical electrical equipment - Part 2-61: Particular requirements for basic safety and essential performance of pulse oximeter equipment (ISO 80601-2-61:2017, corrected version 2018-02)