ÖVE/ÖNORM EN 50395
Issue date: 2012 04 01
Electrical test methods for low voltage energy cables (english version)
EN 50395 contains electrical test methods required for the testing of harmonized low voltage energy
cables, especially those rated at up to and including 450/750 V.
T...
Valid
Publisher:
Austrian Standards International
Format:
Digital | 20 Pages
Language:
English
ICS
EN 50395 contains electrical test methods required for the testing of harmonized low voltage energy
cables, especially those rated at up to and including 450/750 V.
The particular cable standard dictates the tests which need to be performed on the relevant cable
type. It also specifies whether the specific test is a type test (T), a sample test (S) or a routine test (R)
for the particular cable type.
The requirements to be met during or after the test are specified for the particular cable type in the
relevant cable standard. However, some test requirements are obvious and universal, such as the fact
that no breakdown shall occur during voltage tests, and these are stated in the particular test method.
Test methods for use specifically in utility power cables are not covered by this European Standard.
They can be found in HD 605.
Test methods for use specifically in communications cables are the responsibility of the Technical
Committee CENELEC TC 46X, Communication cables. At present such test methods are given in
EN 50289 series.
ÖVE/ÖNORM EN 50395
2012 04 01
Electrical test methods for low voltage energy cables (english version)
Norm
↖
ÖVE/ÖNORM E 8240-2/A1
2003 11 01
Cables of rated voltages up to and including 450/750 V and having cross-linked insulation - Part 2: ...
Norm
ÖVE/ÖNORM E 8241-2+A1
2003 11 01
Cables of rated voltages up to and including 450/750 V and having thermoplastic insulation - Part 2:...
Norm
ÖVE K 40-2
1998 06
Rubber insulated cables of rated voltages up to and including 450/750 V - Part 2: Test methods
Technische Regel
ÖVE K 41-2
1998 06
Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 2: Test m...
Technische Regel
ÖVE K 70-6
1993 05
Prüfverfahren für Kabel, isolierte Leitungen und isolierte Drähte - Sonstige Prüfungen
Technische Regel
ÖVE K 70-5a
1993 05
Prüfverfahren für Kabel, isolierte Leitungen und isolierte Drähte - Prüfung des Verhaltens gegenüber...
Technische Regel
ÖVE K 70-3/1988
1989 09 30
Prüfverfahren für Kabel, isolierte Leitungen und isolierte Drähte - Prüfung elektrischer Eigenschaft...
Technische Regel
ÖVE K 40a/1982
1982 10 01
Nachtrag a zu den Bestimmungen über Energieleitungen mit einer Isolierung aus Gummi, ÖVE-K 40/1978
Technische Regel
ÖVE K 40/1978
1978 01 01
Energieleitungen mit einer Isolierung aus Gummi - einschließlich des Nachtrages ÖVE-K 40a/1982
Technische Regel