Please select and order
€160.20
excl. VAT
Add to cart
Norm
ÖNORM EN ISO 1452-3
Issue date: 2020 03 01
Plastics piping systems for water supply and for buried and above-ground drainage and sewerage under pressure - Unplasticized poly(vinyl chloride) (PVC-U) - Part 3: Fittings
This part of ISO 1452 specifies the characteristics of fittings made from unplasticized poly(vinyl chloride)
(PVC-U) for piping systems intended for water supply and for...
Valid
Publisher:
Austrian Standards International
Format:
Digital | 62 Pages
Language:
German
| English
| Download GER/ENG
Optionally co-design standards:
Topics
show all
Building services engineering & equipment, Supply and disposal systems for buildings, Water supply systems
Building services engineering & equipment, Water supply, External water conveyance systems
Building services engineering & equipment, Water supply, Water supply systems
Construction products, Plastics pipes, Plastics fittings
Construction products, Plastics pipes, Plastics pipes
This part of ISO 1452 specifies the characteristics of fittings made from unplasticized poly(vinyl chloride)
(PVC-U) for piping systems intended for water supply and for buried and above-ground drainage and
sewerage under pressure.
It also specifies the test parameters for the test methods referred to in this part of ISO 1452.
In conjunction with ISO 1452-1, ISO 1452-2 and ISO 1452-5, it is applicable to PVC-U fittings and to joints
with components of PVC-U, other plastics and non-plastics materials intended to be used for the following:
a) water mains and services buried in the ground;
b) conveyance of water above ground for both outside and inside buildings;
c) buried and above-ground drainage and sewerage under pressure.
It is applicable to fittings in piping systems intended for the supply of water under pressure up to and including
25 °C (cold water), intended for human consumption and for general purposes as well as for waste water
under pressure.
This part of ISO 1452 is also applicable to components for the conveyance of water and waste water up to
and including 45 °C. For temperatures between 25 °C and 45 °C, Figure A.1 of ISO 1452-2:2009 applies.
Depending on the jointing method, this part of ISO 1452 is applicable to the following types of fittings:
- fittings for solvent cementing;
- elastomeric ring seal fittings.
PVC-U fittings can be manufactured by injection-moulding and/or be fabricated from pipe.
This part of ISO 1452 is also applicable to PVC-U flange adapters and to the corresponding flanges made
from various materials.
This part of ISO 1452 covers a range of fitting sizes and pressure classes and gives requirements concerning
colours.
ÖNORM EN ISO 1452-3
2020 03 01
Plastics piping systems for water supply and for buried and above-ground drainage and sewerage under...
Norm
↖
ÖNORM EN ISO 1452-3
2010 10 15
Plastics piping systems for water supply and for buried and above-ground drainage and sewerage under...
Norm
ÖNORM EN 1456-1
2002 08 01
Plastics piping systems for buried and above-ground drainage and sewerage under pressure - Unplastic...
Norm
ÖNORM EN 1452-3
2000 02 01
Plastics piping systems for water supply - Unplasticized poly(vinyl chloride) (PVC-U) - Part 3: Fitt...
Norm
Norm
Issue date :
1994 05 12
Pipe threads where pressure-tight joints are made on the threads — Part 1: Dimensions, tolerances and designation
Norm
Issue date :
2005 03 07
Plastics piping and ducting systems — Injection-moulded thermoplastics fittings — Methods for visually assessing the effects of heating
Norm
Issue date :
2006 01 30
Thermoplastics pipes, fittings and assemblies for the conveyance of fluids — Determination of the resistance to internal pressure — Part 1: General method
Norm
Issue date :
2007 10 30
Thermoplastics pipes, fittings and assemblies for the conveyance of fluids — Determination of the resistance to internal pressure — Part 3: Preparation of components
Norm
Issue date :
2004 01 19
Plastics — Methods for determining the density of non-cellular plastics — Part 1: Immersion method, liquid pyknometer method and titration method
Norm
Issue date :
2009 12 01
Plastics piping systems for water supply and for buried and above-ground drainage and sewerage under pressure — Unplasticized poly(vinyl chloride) (PVC-U) — Part 1: General
Norm
Issue date :
2009 12 01
Plastics piping systems for water supply and for buried and above-ground drainage and sewerage under pressure — Unplasticized poly(vinyl chloride) (PVC-U) — Part 2: Pipes
Norm
Issue date :
2009 12 01
Plastics piping systems for water supply and for buried and above-ground drainage and sewerage under pressure — Unplasticized poly(vinyl chloride) (PVC-U) — Part 5: Fitness for purpose of the system (Corrected version 2009-12)
Norm
Issue date :
1995 02 02
Thermoplastics pipes and fittings — Vicat softening temperature — Part 1: General test method
Norm
Issue date :
1995 02 02
Thermoplastics pipes and fittings — Vicat softening temperature — Part 2: Test conditions for unplasticized poly(vinyl chloride) (PVC-U) or chlorinated poly(vinyl chloride) (PVC-C) pipes and fittings and for high impact resistance poly (vinyl chloride) (PVC-HI) pipes
Norm
Issue date :
2005 03 16
Plastics piping systems — Plastics components — Determination of dimensions
Norm
Issue date :
1997 08 28
Plastics piping systems — Unplasticized poly(vinyl chloride) (PVC-U) end-load-bearing double-socket joints — Test method for leaktightness and strength while subjected to bending and internal pressure