Please select and order
€84.27
excl. VAT
Add to cart
Norm

ÖNORM EN ISO 10993-13

Issue date: 2010 10 01

Biological evaluation of medical devices - Part 13: Identification and quantification of degradation products from polymeric medical devices (ISO 10993-13:2010)

This part of ISO 10993 provides general requirements for the design of tests in a simulated environment for identifying and quantifying degradation products from finished...
Valid
Publisher:
Austrian Standards International
Format:
Digital | 23 Pages
Language:
German | English | Download GER/ENG
Optionally co-design standards:
This part of ISO 10993 provides general requirements for the design of tests in a simulated environment for identifying and quantifying degradation products from finished polymeric medical devices ready for clinical use. This part of ISO 10993 describes two test methods to generate degradation products, an accelerated degradation test as a screening method and a real-time degradation test in a simulated environment. For materials that are intended to polymerize in situ, the set or cured polymer is used for testing. The data generated are used in the biological evaluation of the polymer. This part of ISO 10993 considers only non-resorbable polymers. Similar but appropriately modified procedures may be applicable for resorbable polymers. This part of ISO 10993 considers only those degradation products generated by a chemical alteration of the finished polymeric device. It is not applicable to degradation of the device induced during its intended use by mechanical stress, wear or electromagnetic radiation or biological factors such as enzymes, other proteins and cellular activity. The biological activity of the debris and soluble degradation products is not addressed in this part of ISO 10993, but should be evaluated according to the principles of ISO 10993-1, ISO 10993-16 and ISO 10993-17. Because of the wide range of polymeric materials used in medical devices, no specific analytical techniques are identified or given preference. No specific requirements for acceptable levels of degradation products are provided in this part of ISO 10993.
ÖNORM EN ISO 10993-13
2010 10 01
Biological evaluation of medical devices - Part 13: Identification and quantification of degradation...
Norm
ÖNORM EN ISO 10993-13
2009 09 15
Biological evaluation of medical devices - Part 13: Identification and quantification of degradation...
Norm
ÖNORM EN ISO 10993-13
1999 05 01
Biological evaluation of medical devices - Part 13: Identification and quantification of degradation...
Norm
Norm
ISO 3696:1987
Issue date : 1987 04 09
Water for analytical laboratory use — Specification and test methods
Norm
ISO 10993-1:2018
Issue date : 2018 08 17
Biological evaluation of medical devices — Part 1: Evaluation and testing within a risk management process (Corrected version 2018-10)
Norm
ISO 10993-9:2019
Issue date : 2019 11 26
Biological evaluation of medical devices — Part 9: Framework for identification and quantification of potential degradation products
Norm
ISO 10993-17:2002
Issue date : 2002 11 27
Biological evaluation of medical devices — Part 17: Establishment of allowable limits for leachable substances
Norm
ISO 10993-13:2010
Issue date : 2010 06 04
Biological evaluation of medical devices — Part 13: Identification and quantification of degradation products from polymeric medical devices