Please select and order
€120.67
excl. VAT
Add to cart
Norm
ÖNORM EN 416-2
Issue date: 2006 11 01
Single burner gas-fired overhead radiant tube heaters for non-domestic use - Part 2: Rational use of energy
This European Standard specifies the requirements and test methods for the rational use of energy of non-domestic gas fired overhead radiant tube heaters incorporating a ...
Withdrawn: 2020 04 15
§ Legal References
Publisher:
Austrian Standards International
Format:
Digital | 49 Pages
Language:
German
| English
| Download GER/ENG
Currently valid:
Optionally co-design standards:
ICS
This European Standard specifies the requirements and test methods for the rational use of energy of non-domestic gas fired overhead radiant tube heaters incorporating a single burner system under the
control of an automatic burner control system, referred to in the body of the text as appliances.
This standard is applicable to Type A2, A3, B12, B13, B22, B23, B42, B43, B52, B53, C12, C13, C32 and C33
appliances intended for use in other than domestic dwellings, in which the supply of combustion air
and/or the evacuation of the products of combustion is achieved by mechanical means located
upstream of the draught diverter, if provided.
This standard is not applicable to:
a) appliances designed for use in a domestic dwelling;
b) outdoor appliances;
c) appliances of heat input in excess of 120 kW (based on the net calorific value of the
appropriate reference test gas);
d) appliances having fully pre-mixed gas and air burners in which :
1) either the gas and all the combustion air are brought together just before the level of the
combustion zone; or
2) pre-mixing of the gas and all combustion air is carried out in a part of the burner
upstream of the combustion zone.
This standard is applicable to appliances which are intended to be type tested. Requirements for
appliances which are not intended to be type tested need to be subject to further consideration.
ÖNORM EN 416
2020 04 15
Gas-fired overhead radiant tube heaters and radiant tube heater systems for non-domestic use - Safet...
Norm
ÖNORM EN 17175
2020 04 15
Gas-fired overhead radiant strip heaters and multi-burner continuous radiant tube heater systems for...
Norm
ÖNORM EN 416
2020 03 15
Gas-fired overhead radiant tube heaters and radiant tube heater systems for non-domestic use - Safet...
Norm
ÖNORM EN 416-2
2006 11 01
Single burner gas-fired overhead radiant tube heaters for non-domestic use - Part 2: Rational use of...
Norm
↖
ÖNORM ENV 1259-2
1998 03 01
Single burner gas-fired overhead radiant tube heaters and non-domestic gas-fired overhead luminous r...
Vornorm
ÖNORM ENV 1259-3
1998 03 01
Single burner gas-fired overhead radiant tube heaters and non-domestic gas-fired overhead luminous r...
Vornorm
ÖNORM ENV 1259-2
1996 06 01
Single burner gas-fired overhead radiant tube heaters and non-domestic gas-fired overhead luminous r...
Vornorm Entwurf
ÖNORM ENV 1259-3
1996 06 01
Single burner gas-fired overhead radiant tube heaters and non-domestic gas-fired overhead luminous r...
Vornorm Entwurf
ÖNORM ENV 1259-1
1994 09 01
Single burner gas-fired overhead radiant tube heaters and non-domestic gas-fired overhead luminous r...
Vornorm
Norm
Issue date :
1999 09 01
Single burner gas-fired overhead radiant-tube heaters - Part 1: Safety
Norm
Issue date :
2006 10 01
Single burner gas-fired overhead radiant tube heaters for non-domestic use - Part 1: Safety (including amendments A1:2000, A2:2001 and A3:2002)
Norm
Issue date :
2020 04 15
Gas-fired overhead radiant strip heaters and multi-burner continuous radiant tube heater systems for non-domestic use - Safety and energy efficiency
Norm
Issue date :
2020 03 15
Gas-fired overhead radiant tube heaters and radiant tube heater systems for non-domestic use - Safety and energy efficiency