Please select and order
€160.20
excl. VAT
Add to cart
Norm
ÖNORM EN 1634-2
Issue date: 2009 02 01
Fire resistance and smoke control tests for door, shutter and openable window assemblies and elements of building hardware - Part 2: Fire resistance characterisation test for elements of building hardware
This European Standard specifies a method for characterizing the influence on fire performance of
items of building hardware for incorporation into hinged or pivoted ver...
Valid
Publisher:
Austrian Standards International
Format:
Digital | 64 Pages
Language:
German
| English
| Download GER/ENG
Optionally co-design standards:
This European Standard specifies a method for characterizing the influence on fire performance of
items of building hardware for incorporation into hinged or pivoted vertically installed fire door
assemblies (having either one or two leaves) or vertically installed openable window assemblies, of
known fire resistance of up to and including 240 minutes integrity (and where relevant insulation) in
accordance with EN 1634-1. It applies to the testing of building hardware for use on hinged and
pivoted doors and openable windows which include framed glazed doors and windows, but not glass
doors. It does not include a test for durability or other performance characteristics, which should be
evaluated according to the product standard for the item of building hardware or as given in
EN 14600.
The method is suitable for characterizing building hardware for use on non-metallic door or window
assemblies consisting of cellulosic materials or mineral boards faced with cellulosic materials, hung in
either cellulosic, mineral cored or metal frames: or conventional steel doors made from sheet steel,
not more than 1,5 mm thick, hung in steel frames (steel doors include doors filled with mineral board
or mineral fibre cores but not steel clad timber/cellulosic doors). The size of these assemblies can be
up to that given in the field of direct application for the door leaf construction concerned.
This method is not directly appropriate for evaluating building hardware for use on glass or glazed
doors with decorative perimeter framing. The appropriateness of this method of test can be
established by reference to the flow chart given in Annex A.
This European Standard does not constitute a fire resistance test for a leaf, window, frame,
intumescent seal, or anything other than the selected item of building hardware. The use of any
resulting field of direct application is restricted to leaf and frame constructions whi (...abbreviated)
ÖNORM EN 1634-2
2009 02 01
Fire resistance and smoke control tests for door, shutter and openable window assemblies and element...
Norm
↖
Norm
Issue date :
2004 03 01
Building hardware - Single-axis hinges - Requirements and test methods (EN 1935:2002 + AC:2003)
Norm
Issue date :
2006 03 01
Doorsets and openable windows with fire resisting and/or smoke control characteristics - Requirements and classification
Norm
Issue date :
2009 12 01
Fire classification of construction products and building elements - Part 1: Classification using data from reaction to fire tests
Norm
Issue date :
2014 02 15
Fire resistance and smoke control tests for door and shutter assemblies, openable windows and elements of building hardware - Part 1: Fire resistance test for door and shutter assemblies and openable windows
Norm
Issue date :
2023 01 01
Fire resisting doorsets and/or smoke control doorsets - Requirements and tests for single and multiple leaf constructions