Please select and order
€171.12
excl. VAT
Add to cart
Norm
ÖNORM EN 1634-1
Issue date: 2009 02 01
Fire resistance and smoke control tests for door, shutter and openable window assemblies and elements of building hardware - Part 1: Fire resistance tests for doors, shutters and openable windows
This Part of EN 1634 specifies a method for determining the fire resistance of doors, shutters and
openable windows designed for installation within openings incorporate...
Withdrawn: 2014 02 15
§ Legal References
Publisher:
Austrian Standards International
Format:
Digital | 75 Pages
Language:
German
| English
| Download GER/ENG
Currently valid:
Optionally co-design standards:
This Part of EN 1634 specifies a method for determining the fire resistance of doors, shutters and
openable windows designed for installation within openings incorporated in vertical separating
elements, such as:
- hinged or pivoted doors;
- horizontally sliding and vertically sliding doors including articulated sliding doors and sectional
doors;
- sliding folding doors and shutters;
- tilting doors;
- rolling shutters;
- openable windows;
- openable fabric curtains.
This European Standard is used in conjunction with EN 1363-1.
Doors tested in accordance with this European Standard and classified in accordance with EN 13501-2
may be accepted for lift landing door applications as an alternative to EN 81-58. EN 81-58
represents a specific test for lift landing doors and results in an alternative classification which may
not be suitable for some other purposes as defined in National Regulations.
The testing of fire dampers is covered by EN 1366-2.
The testing of closures for conveyor systems is covered by EN 1366-7.
Further requirements are described in the relevant product standard and in the supporting standard
EN 14600.
This method may also be used to determine the fire resistance of non-loadbearing horizontally
orientated doors, shutters and openable windows by analogy. However, these are not specifically
addressed here and the field of direct application given in Clause 13 is not valid for such horizontally
orientated products.
By prior agreement with the test sponsor additional information may be gained for individual elements
of building hardware. Based on the observations recorded during the test, the results may be
presented in a separate report.
ÖNORM EN 1634-1
2018 05 01
Fire resistance and smoke control tests for door and shutter assemblies, openable windows and elemen...
Norm
ÖNORM EN 1634-1
2016 06 01
Fire resistance and smoke control tests for door and shutter assemblies, openable windows and elemen...
Norm
ÖNORM EN 1634-1
2014 02 15
Fire resistance and smoke control tests for door and shutter assemblies, openable windows and elemen...
Norm
ÖNORM EN 1634-1
2009 02 01
Fire resistance and smoke control tests for door, shutter and openable window assemblies and element...
Norm
↖
ÖNORM EN 1634-1
2007 02 01
Fire resistance and smoke control tests for door and shutter assemblies, openable windows and elemen...
Norm
ÖNORM EN 1634-1
2000 10 01
Fire resistance tests for door and shutter assemblies - Part 1: Fire doors and shutters
Norm
Norm
Issue date :
2000 01 01
Fire resistance tests - Part 2: Alternative and additional procedures
Norm
Issue date :
2006 03 01
Doorsets and openable windows with fire resisting and/or smoke control characteristics - Requirements and classification
Norm
Issue date :
2010 02 15
Fire classification of construction products and building elements - Part 2: Classification using data from fire resistance tests, excluding ventilation services
Norm
Issue date :
2014 02 15
Fire resistance and smoke control tests for door and shutter assemblies, openable windows and elements of building hardware - Part 1: Fire resistance test for door and shutter assemblies and openable windows