Please select and order
€120.67
excl. VAT
Add to cart
Norm

ÖNORM EN 15502-2-2

Issue date: 2014 11 01

Gas-fired central heating boilers - Part 2-2: Specific standard for type B1 appliances

This European Standard specifies, the requirements and test methods concerning, in particular the construction, safety, fitness for purpose, and rational use of energy, ...
Valid
This European Standard specifies, the requirements and test methods concerning, in particular the construction, safety, fitness for purpose, and rational use of energy, as well as the classification and marking of gas-fired central heating boilers that are fitted with atmospheric burners, fan assisted atmospheric burners and are hereafter referred to as "boilers". Where the word boiler is used, it must be read as the boiler including its connecting ducts, ducts and terminals, if any. This European Standard covers gas-fired central heating boilers type B11, B11BS, B12, B12BS, B13, B13BS according to the classification in CEN/TR 1749:2009: a) that have a nominal heat input (on the basis of net calorific value) not exceeding 70 kW; b) that use one or more combustible gases of the three gas families at the pressures stated in EN 437; c) where the temperature of the heat transfer fluid does not exceed 105 °C during normal operation; d) where the maximum operating pressure in the water circuit does not exceed 6 bar; e) Which can give rise to condensation under certain circumstances; f) which are declared in the installation instructions to be either a "low temperature boiler" or a "standard boiler". If no declaration is given the boiler is to be considered a "standard boiler" g) which are intended to be installed either indoors or in a partially protected place; h) which are either not intended to produce hot water, or are intended to produce hot water either by the instantaneous or storage principle, the whole being marketed as a single unit. i) which are designed for either sealed water systems or for open water systems j) which are either modular boilers, or no modular boilers. This European Standard is to be used in conjunction with the General Requirements Standard EN 15502-1. For applications within the scope of the PED further requirements may be necessary (e.g. situations where the maximum allowable temperature exceeds 110 °C, or where volume times maximum allowable pressure is over 50 bar x litres). This standard provides requirements for boilers with known constructions. For boilers with any alternative constructions, which might not fully be covered by this standard, the risk associated with this alternative construction shall be assessed. An example of an assessment methodology, based upon risk assessment and which covers the essential requirements of the Gas Appliance Directive, is given in Clause 11.
ÖNORM EN 15502-2-2
2014 11 01
Gas-fired central heating boilers - Part 2-2: Specific standard for type B1 appliances
Norm
ÖNORM EN 15417
2006 11 01
Gas-fired central heating boilers - Specific requirements for condensing boilers with a nominal heat...
Norm
ÖNORM EN 297
2006 10 01
Gas-fired central heating boilers - Type B boilers, fitted with atmospheric burners of nominal heat ...
Norm
ÖNORM EN 297
2005 07 01
Gas-fired central heating boilers - Type B boilers, fitted with atmospheric burners of nominal heat ...
Norm
ÖNORM EN 297/A6
2003 06 01
Gas-fired central heating boilers - Type B11 and B11BS boilers, fitted with atmospheric burners of n...
Norm
ÖNORM EN 297/A5
1998 10 01
Gas-fired central heating boilers - Type B11 and B 11BS boilers, fitted with atmospheric burners of ...
Norm
ÖNORM EN 677
1998 08 01
Gas-fired central heating boilers - Specific requirements for condensing boilers with a nominal heat...
Norm
ÖNORM EN 297/A3
1997 03 01
Gas-fired central heating boilers - Type B11 and B11BS boilers fitted with atmospheric burners of no...
Norm
ÖNORM EN 297
1996 10 01
Gas-fired central heating boilers - Type B11 and B11BS boilers fitted with atmospheric burners of no...
Norm
ÖNORM EN 625
1996 02 01
Gas-fired central heating boilers - Specific requirements for the domestic hot water operation of co...
Norm
ÖNORM EN 297
1994 09 01
Gas-fired central heating boilers - Type B11 and B11BS boilers fitted with atmospheric burners of no...
Norm
ÖNORM M 7446
1992 05 01
Condensing appliances for gaseous fuels - Requirements, disposal of condensate, flue ducting, testin...
Norm
ÖNORM M 7446
1985 04 01
Condensing appliances for gaseous fuels; requirements, disposal of condensate and flue ducting, test...
Vornorm
ÖNORM M 7447
1983 05 01
Gas-fired circulation heaters and combined water heaters
Norm
Expand
Norm
ÖNORM EN 437
Issue date : 2009 07 01
Test gases - Test pressures - Appliance categories
Norm
ÖNORM EN 14459
Issue date : 2009 01 01
Control functions in electronic systems for gas burners and gas burning appliances - Methods for classification and assessment (consolidated version)
Norm
ÖNORM EN 15502-1
Issue date : 2015 09 15
Gas-fired heating boilers - Part 1: General requirements and tests