ÖNORM EN 1422
Issue date: 1998 03 01
Sterilizers for medical purposes - Ethylene oxide sterilizers - Requirements and test methods
This European standard specifies the minimum performance requirements and test methods of two types of sterilizers employing ethyiene oxide gas as the sterilant, either a...
Withdrawn: 2010 01 01
§ Legal References
Publisher:
Austrian Standards International
Format:
Digital | 53 Pages
Language:
German
| English
Currently valid:
Optionally co-design standards:
ICS
This European standard specifies the minimum performance requirements and test methods of two types of sterilizers employing ethyiene oxide gas as the sterilant, either as a pure gas or in admixture with other gases (whether supplied ready mixed or mixed at the point of use) in a temporarily sealed chamber. These sterilizers are intended to be used for medical, dental, pharmaceutical, veterinary and industrial or related purposes. The two types of sterilizers have been designated Type A and Type B respectively using the fotlowing criteria: Type A sterilizers are capable of being programmed by the user; Type B sterilizers are of limited size and provided with one or more pre-set operating cycles which cannot
be varied by the user. The clauses of this standard apply to both types of sterilizers unless it is specifically indicated within the clause that it applies only to one of the types in particular. This standard includes minimum performance and construction requirements for sterilizers working above or below atmospheric pressure: to ensure that the process is capable of being used to sterilize medical products; for the equipment and controls necessary to permit validation and monitoring of the steriiization process. This standard does not specify those tests which are necessary to determine the probability of a processed product being sterile, nor the routine quality control tests required prior to release of sterile product. These topics are addressed in EN 550. This standard does not specify the procedures and equipment which can be used to improve the efficacy and/or efficiency of the process before or after the sterilization cycle.
Considerations of Operator safety are addressed in EN 6100-1 + A2 and IEC 101 0-2-042. This standard is applicable when:
a) spebified in a contract for supply of an ethylene oxide sterilizer;
b) a sterilizer rnanufacturer declares compliance when intending to supply an ethylene o (...abbreviated)
ÖNORM EN 1422
2014 08 15
Sterilizers for medical purposes - Ethylene oxide sterilizers - Requirements and test methods
Norm
ÖNORM EN 1422
2009 09 15
Sterilizers for medical purposes - Ethylene oxide sterilizers - Requirements and test methods
Norm
ÖNORM EN 1422
1998 03 01
Sterilizers for medical purposes - Ethylene oxide sterilizers - Requirements and test methods
Norm
↖
Norm
Issue date :
2000 09 21
Pipe threads where pressure-tight joints are not made on the threads — Part 1: Dimensions, tolerances and designation
Norm
Issue date :
2003 11 25
Flat pallets for intercontinental materials handling — Principal dimensions and tolerances (Corrected version 2004-04)
Norm
Issue date :
2009 12 01
Acoustics - Determination of sound power levels of noise sources using sound pressure - Survey method using an enveloping measurement surface over a reflecting plane (ISO 3746:1995, including Cor 1:1995)
Norm
Issue date :
2006 11 01
Sterilization of health care products - Biological indicators - Part 1: General requirements (ISO 11138-1:2006)
Norm
Issue date :
2009 09 15
Packaging for terminally sterilized medical devices - Part 4: Paper bags - Requirements and test methods
Norm
Issue date :
2009 09 15
Packaging for terminally sterilized medical devices - Part 5: Sealable pouches and reels of porous materials and plastic film construction - Requirements and test methods
Norm
Issue date :
2009 09 15
Sterilizers for medical purposes - Ethylene oxide sterilizers - Requirements and test methods