Inlet valves for flushing cisterns with internal overflow
The purpose of this document is to specify:
the dimensional, hygiene, tightness, pressure performance, hydraulic, acoustic, mechanical and
physico-chemical characteris...
Valid
§ Legal References
Publisher:
Austrian Standards International
Format:
Digital | 22 Pages
Language:
German
| English
| Download GER/ENG
Optionally co-design standards:
ICS
The purpose of this document is to specify:
the dimensional, hygiene, tightness, pressure performance, hydraulic, acoustic, mechanical and
physico-chemical characteristics which inlet valves for flushing cisterns shall comply with;
the test methods for testing these characteristics;
marking and presentation.
This document applies exclusively to the valve itself and it does not prejudge compliance with health regulations as
the inlet valve is being fitted into the cistern.
This document does not cover valves intended to equip flushing cisterns with external overflow.
This document applies to valves such as float valves limit operating at pressures up to NP 10 (whose operating
range is from 0,05 MPa to 1 MPa ¿ 0,5 bar to 10 bar) designed to supply cold water to flushing cisterns for use with
WC pans, that are permanently connected to a potable water supply system.
The working range can be extended downwards (< 0,05 MPa ¿ 0,5 bar) down to 0,01 MPa (0,1 bar), in which case
the manufacturer¿s instructions shall indicate this possibility as well as the recommended working range.
Range which shall be covered
Optional range
This document does not apply to valves used for other applications: pumping tanks, storage tanks, etc.
Norm
Issue date :
2008 04 01
Protection against pollution of potable water in water installations and general requirements of devices to prevent pollution by backflow
Norm
Issue date :
2003 06 01
Pipe threads where pressure-tight joints are not made on the threads - Part 1: Dimensions, tolerances and designation (ISO 228-1:2000)
Norm
Issue date :
1999 07 01
Acoustics - Laboratory tests on noise emission from appliances and equipment used in water supply installations - Part 1: Method of measurement (ISO 3822-1:1999)
Norm
Issue date :
1997 07 01
Acoustics - Laboratory tests on noise emission from appliances and equipment used in water supply installations - Part 4: Mounting and operating conditions for special appliances
Norm
Issue date :
2003 12 01
Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 1: General principles and requirements (ISO 5167-1:2003)
Norm
Issue date :
2003 12 01
Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 2: Orifice plates (ISO 5167-2:2003)
Norm
Issue date :
2003 12 01
Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 3: Nozzles and Venturi nozzles (ISO 5167-3:2003)
Norm
Issue date :
2003 12 01
Measurement of fluid flow by means of pressure differential devices inserted in ciruclar cross-section conduits running full - Part 4: Venturi tubes (ISO 5167-4:2003)