Please select and order
€98.22
excl. VAT
Add to cart
Norm

ÖNORM EN 1264-3

Issue date: 2021 08 01

Water based surface embedded heating and cooling systems - Part 3: Dimensioning

The EN 1264 series gives guidelines for surface embedded heating and cooling systems installed in buildings, residential and non-residential (e.g. office, public, commerc...
Valid
Publisher:
Austrian Standards International
Format:
Digital | 23 Pages
Language:
German | English | Download GER/ENG
Optionally co-design standards:
The EN 1264 series gives guidelines for surface embedded heating and cooling systems installed in buildings, residential and non-residential (e.g. office, public, commercial and industrial buildings) and focuses on systems installed for the purpose of thermal comfort. The EN 1264 series gives guidelines for water based heating and cooling systems embedded into the enclosure surfaces of the room to be heated or to be cooled. It also specifies the use of other heating media instead of water, as appropriate. The EN 1264 series specifies standardized product characteristics by calculation and testing the thermal output of heating for technical specifications and certification. For the design, construction and operation of these systems, see EN 1264-3 and EN 1264-4 for the types A, B, C, D, H, I and J. For the types E, F and G, see the EN ISO 11855 series. The systems specified in the EN 1264 series are adjoined to the structural base of the enclosure surfaces of the building, mounted directly or with fixing supports. The EN 1264 series does not specify ceiling systems mounted in a suspended ceiling with a designed open air gap between the system and the building structure which allows the thermally induced circulation of the air. The thermal output of these systems can be determined according to EN 14037 series and EN 14240. EN 1264-3 specifies the use in practical engineering of the results coming from EN 1264-2 and EN 1264-5. For heating systems, physiological limitations are taken into account when specifying the surface temperatures. In the case of floor heating systems the limitations are realized by a design based on the characteristic curves and limit curves determined in accordance with EN 1264-2. For cooling systems, only a limitation with respect to the dew point is taken into account. In predominating practice, this means that physiological limitations are included as well.
ÖNORM EN 1264-3
2021 08 01
Water based surface embedded heating and cooling systems - Part 3: Dimensioning
Norm
ÖNORM EN 1264-3
2009 10 01
Water based surface embedded heating and cooling systems - Part 3: Dimensioning
Norm
ÖNORM EN 15377-2
2008 12 01
Heating systems in buildings - Design of embedded water based surface heating and cooling systems - ...
Norm
ÖNORM EN 1264-3
1998 05 01
Floor heating - Systems and components - Part 3: Dimensioning
Norm
ÖNORM M 7560-2
1984 09 01
Floor heatings; quality requirements
Norm
Expand