Controls for heating systems - Part 2: Optimum start-stop control equipment for hot water heating systems
This standard applies to electronic equipment which controls heating systems with water as the
heating medium and a flow temperature up to 120 °C. The signals can be pro...
Withdrawn: 2013 10 15
Publisher:
Austrian Standards International
Format:
Digital | 26 Pages
Language:
German
| English
| Download GER/ENG
Currently valid:
Optionally co-design standards:
Topics
show all
Mechanical & plant engineering, Heating systems, Central heating systems
IT, communication & electronic, Domestic engineering, Automatic controls for household use
Electric & lighting engineering, Domestic engineering, Automatic controls for household use
Building services engineering & equipment, Heating systems, Central heating systems
Building services engineering & equipment, Domestic engineering, Automatic controls for household use
Safety, Domestic engineering, Automatic controls for household use
This standard applies to electronic equipment which controls heating systems with water as the
heating medium and a flow temperature up to 120 °C. The signals can be processed by using
either analogue or digital techniques, or both. The particular equipment to which this standard
applies covers both :
stand-alone start optimisers or start-stop optimisers, taking priority to the main controller
during periods.
controllers which contain an integrated optimum start or an optimum start-stop control
function.
It applies both to adaptive and fixed parameters control functions and sets minimum acceptable
standards for functions, performance and documentation.
NOTE The optimum start-stop function can be integrated within a main control device such as an
outside temperature compensated (OTC) controller. In this case the controller would be expected to meet
both Part 1 and Part 2 of this standard (see EN 12098-1:1996).
Safety requirements on heating systems and heating control systems remain unaffected by this
standard. The actuators and the dynamic behaviour of the valves are not covered in this
standard.
This control equipment may or may not be connected to a data network.
ÖNORM EN 12098-1
2023 06 01
Energy performance of buildings - Controls for heating systems - Part 1: Control equipment for hot w...
Norm
ÖNORM EN 12098-1
2017 12 01
Energy Performance of Buildings - Controls for heating systems - Part 1: Control equipment for hot w...
Norm
ÖNORM EN 12098-1
2013 10 15
Controls for heating systems - Part 1: Control equipment for hot water heating systems
Norm
ÖNORM EN 12098-2
2001 09 01
Controls for heating systems - Part 2: Optimum start-stop control equipment for hot water heating sy...
Norm
↖
Norm
Issue date :
2013 10 15
Controls for heating systems - Part 1: Control equipment for hot water heating systems
Norm
Issue date :
2013 10 15
Controls for heating systems - Part 1: Control equipment for hot water heating systems