Please select and order
€98.22
excl. VAT
Add to cart
Norm
ÖNORM EN 1076
Issue date: 1997 07 01
Workplace atmospheres - Pumped sorbent tubes for the determination of gases and vapours - Requirements and test methods
This European Standard specifies performance requirements and test methods under prescribed laboratory
conditions for a pumped sorbent tube used in conjunction with an a...
Withdrawn: 2010 02 15
Publisher:
Austrian Standards International
Format:
Digital | 25 Pages
Language:
German
| English
Currently valid:
Optionally co-design standards:
ICS
This European Standard specifies performance requirements and test methods under prescribed laboratory
conditions for a pumped sorbent tube used in conjunction with an air sampling pump for the determination of
gases and vapours in workplace atmospheres.
Additional tests designed to establish whether the performance characteristics of the pumped sorbent tube are
affected by the wider range of environmental influences that may be encountered in field use are described in
annexes C and D.
If there is no pumped sorbent tube for measuring a particular chemical agent which meets the requirements of
this European Standard, it is recommended to use a pumped sorbent tube whose performance is nearest to the
specif ied requirements,
Some of the test methods described in this European Standard require the use of an air sampling pump. The
specification for such a pump is covered by EN 1232.
The European Standard is applicable to pumped sorbent tubes which are used for the indirect determination of
concentrations, by sampling and analysis in separate Stages.
These tubes can be divided into:
- type A samplers which rely on sorption onto a solid or onto a support impregnated with a reagent, desorption
with solvent, and subsequent analysis of the desorbate;
- type B samplers which rely on sorption onto a solid or onto a support impregnated with a reagent, desorption
by heat, and analysis of the desorbate.
NOTE 1 : Type A samplers usually consist of two beds of sorbent in series, i.e. with a back-up section,
and contain an active sorbent (e. g. charcoal) or a support impregnated with reagent. The back-up section
is not used in the breakthrough tests, but in field use is a protection against unexpected breakthrough.
NOTE 2: Type B samplers usually consist of a single bed of active sorbent (e. g. porous polymer resin).
Specific aspects of the use of reagent impregnated Systems will be covered in additional parts o (...abbreviated)
ÖNORM EN ISO 22065
2021 04 15
Workplace air - Gases and vapours - Requirements for evaluation of measuring procedures using pumped...
Norm
ÖNORM EN ISO 22065
2020 01 01
Workplace air - Gases and vapours - Requirements for evaluation of measuring procedures using pumped...
Norm
ÖNORM EN 1076
2010 02 15
Workplace exposure - Procedures for measuring gases and vapours using pumped samplers - Requirements...
Norm
ÖNORM EN 1076
1997 07 01
Workplace atmospheres - Pumped sorbent tubes for the determination of gases and vapours - Requiremen...
Norm
↖
Norm
Issue date :
2007 06 01
Workplace atmospheres - General requirements for the performance of procedures for the measurement of chemical agents
Norm
Issue date :
2010 03 01
Workplace exposure - Procedures for measuring gases and vapours using diffusive samplers - Requirements and test methods
Norm
Issue date :
1997 05 01
Workplace atmospheres - Pumps for personal sampling of chemical agents - Requirements and test methods
Norm
Issue date :
2010 02 15
Workplace exposure - Procedures for measuring gases and vapours using pumped samplers - Requirements and test methods