Jetzt auswählen und bestellen
56,10 €
exkl. USt.
In den Warenkorb
Icon ISO
Icon ISO
Norm

ISO 389-7:2005

Ausgabedatum: 2005 11 03

Acoustics — Reference zero for the calibration of audiometric equipment — Part 7: Reference threshold of hearing under free-field and diffuse-field listening conditions

ISO 389-7:2005 specifies a reference threshold of hearing for the calibration of audiometric equipment used under the following conditions. The sound field in the absenc...
ZURÜCKGEZOGEN: 2019 11 05
Herausgeber:
International Organization for Standardization
Format:
Digital | 10 Seiten
Sprache:
Englisch
Aktuell Gültig:

ISO 389-7:2005 specifies a reference threshold of hearing for the calibration of audiometric equipment used under the following conditions.

  1. The sound field in the absence of the listener consists of either a free progressive plane wave (free field) or a diffuse sound field, as specified in ISO 8253-2. In the case of a free field, the source of sound is directly in front of the listener (frontal incidence).
  2. The sound signals are pure (sinusoidal) tones in the case of free-field conditions and one-third octave bands of (white or pink) noise in the case of diffuse-field conditions.
  3. The sound pressure level is measured in the absence of the listener at the position where the centre of the listener's head would be.
  4. Listening is binaural.

The data in ISO 389-7:2005 are given in numerical form for the preferred frequencies in the one-third octave series from 20 Hz to 16 000 Hz inclusive in accordance with ISO 266 and, in addition, for some intermediate audiometric frequencies up to 18 000 Hz.

The threshold data differ from the audiometric zero specified in ISO 389-1, ISO 389-2, ISO/TR 389-5 and ISO 389-8, since the latter refer to monaural listening through earphones with sound pressure levels referred to specified couplers and ear simulators. Direct comparison between the data in the parts of ISO 389 mentioned above and that in ISO 389-7:2005 is therefore not appropriate.

ISO 389-7:2019
2019 11 05
Acoustics — Reference zero for the calibration of audiometric equipment — Part 7: Reference threshol...
Norm
ISO 389-7:2005
2005 11 03
Acoustics — Reference zero for the calibration of audiometric equipment — Part 7: Reference threshol...
Norm
ISO 389-7:1996
1996 12 26
Acoustics — Reference zero for the calibration of audiometric equipment — Part 7: Reference threshol...
Norm
Norm
ISO 389-7:2019
Ausgabedatum : 2019 11 05
Acoustics — Reference zero for the calibration of audiometric equipment — Part 7: Reference threshold of hearing under free-field and diffuse-field listening conditions